Available energy analysis of new tandem double-capillary tube refrigeration system for refrigerator-freezers
2016年12月21日 16:42 点击:[]
论文名称: Available energy analysis of new tandem double-capillary tube refrigeration system for refrigerator-freezers
作者: He Maogang, Song Xinzhou*, Zhang Ying*, Zhang Jiantao*
来源出版物: Frontiers of Energy and Power Engineering in China
年卷期页: 2008,2(1):36-42
收录类型: 其他
论文简介: "A new tandem double-capillary tube refrigeration system for refrigerator-freezers is proposed. A
capillary tube was added between the two evaporators in
the fresh and frozen food storage chests to raise the
evaporation temperature of the refrigerating chamber,
and reduce the heat exchange temperature difference and
the available energy loss. Peng-Robinson (P-R) equation
of state was adopted to calculate the thermodynamic
properties of the refrigerants, and the available energy
analysis of the vapor compression refrigeration cycle was
programmed to calculate the thermodynamic performances of the new and the conventional refrigeration
cycle of the refrigerator-freezer. The calculation results
show that the available energy efficiency of the conventional refrigeration cycle of the refrigerator-freezer is
21.20% and 20.57%, respectively when the refrigerant is
R12 and R134a, while that of the double-capillary tube
refrigeration cycle of the refrigerator-freezer is 23.97%
and 23.44%, respectively. By comparison, the available
energy efficiency of the new refrigeration system
increases by 13.07% and 13.95%, respectively."
原文链接: Available energy analysis of new tandem double-capillary tube refrigeration system for refrigerator-freezers