Local measurement of gas-liquid bubbly flow with a double-sensor probe
2016年12月20日 20:39 点击:[]
论文名称: Local measurement of gas-liquid bubbly flow with a double-sensor probe
作者: Sun Kexia, Zhang Mingyuan, Chen Xuejun
来源出版物: Chinese Journal of Chemical Engineering
年卷期页: 2000,8(1):33-40
收录类型: SCI:299JQ;WOS:000086195700006和EI
论文简介: A double-sensor probe was used to measure local interfacial parameters of a gas-liquid bubbly flow in a horizontal tube. The parameters included void fraction, interfacial concentration, bubble size distribution, bubble frequency and bubble interface velocity. The authors paid special attention to the probe design and construction for minimizing measurement errors. Measures were also taken in the design of sensor ends for preventing corrosions in the flow. This is an effort to improve the current double-sensor probe technique to meet the ever-increasing needs to local varameter measurements in gas-liquid two-phase flows.
原文链接: Local measurement of gas-liquid bubbly flow with a double-sensor probe